<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Eduardo Manzanos, autor en Powercloud | Energy monitoring and management</title>
	<atom:link href="https://www.powercloud.es/en/author/eduardo-manzanos/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.powercloud.es/en/author/eduardo-manzanos/</link>
	<description>Monitorización y gestión energética</description>
	<lastBuildDate>Thu, 22 Oct 2026 17:31:54 +0000</lastBuildDate>
	<language>en-GB</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.3.15</generator>

<image>
	<url>https://www.powercloud.es/wp-content/uploads/2019/12/cropped-logo-32x32.png</url>
	<title>Eduardo Manzanos, autor en Powercloud | Energy monitoring and management</title>
	<link>https://www.powercloud.es/en/author/eduardo-manzanos/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Industrial submetering: the meter tells you how much your plant consumes — machine-level metering tells you who</title>
		<link>https://www.powercloud.es/en/industrial-submetering-energy-monitoring-machine-process/</link>
		
		<dc:creator><![CDATA[Eduardo Manzanos]]></dc:creator>
		<pubDate>Tue, 22 Sep 2026 14:46:59 +0000</pubDate>
				<category><![CDATA[Energy Efficiency]]></category>
		<category><![CDATA[Energy Management]]></category>
		<category><![CDATA[Energy Technology]]></category>
		<guid isPermaLink="false">https://www.powercloud.es/?p=7356</guid>

					<description><![CDATA[<p>Today we kick off a three-part series on the path that leaves the most margin in an industrial plant: measure better → calculate the real cost → manage by indicators. Today, the first building block: monitoring by machine and process, what the industry calls submetering.</p>
<p>La entrada <a rel="nofollow" href="https://www.powercloud.es/en/industrial-submetering-energy-monitoring-machine-process/">Industrial submetering: the meter tells you how much your plant consumes — machine-level metering tells you who</a> se publicó primero en <a rel="nofollow" href="https://www.powercloud.es/en">Powercloud | Energy monitoring and management</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Measure better → calculate the real cost → manage by indicators</strong>. These are the three building blocks of an energy management system (EnMS). In this post, we cover the first one: <strong>monitoring by machine and process</strong>, what the industry calls <strong>submetering</strong> — installing secondary metering downstream of the main meter so you know not only how much your plant consumes, but <strong>who, when and what for</strong>. The date is no coincidence: today is the very day <a hreflang="es" href="https://www.powercloud.es/intradiario-96-rondas-arranca-22-septiembre-preparacion-empresas/" target="_blank" rel="noopener">the 96-round intraday market goes live</a> (in Spanish) — the whole market is moving towards <span style="text-decoration: underline;">fine-grained detail</span>, and plant-level metering is the piece most companies are missing if they want to keep pace with it.</p>
<h2>What the main meter can’t tell you</h2>
<p><a hreflang="es" href="https://www.powercloud.es/contadores-inteligentes-espana-50-millones-dato-consumo-empresas/" target="_blank" rel="noopener">The smart meter on your supply</a> (in Spanish) is a great starting point: a quarter-hourly load profile, free of charge and already installed. But it gives you <strong>a single figure for the whole plant</strong>. It tells you that at 11:15 yesterday you were drawing 480 kW; it doesn’t tell you whether that was the compressors, the furnaces, the refrigeration or a valve left open that nobody spotted.</p>
<p>That blind spot has concrete consequences: phantom (idle) consumption at weekends and during shutdowns stays hidden within the total; <a hreflang="es" href="https://www.powercloud.es/procesos-homologos-caes-benchmarking-interno-radar-oportunidades-ahorro/" target="_blank" rel="noopener">two identical lines that consume differently</a> (in Spanish) can’t be compared; and any efficiency project — or its application for CAEs (Spain’s Energy Savings Certificates) — lacks the measurement boundary that a verifier requires.</p>
<h2>What submetering means in practice</h2>
<p>It means installing <strong>secondary metering devices</strong> — panel-mounted power analysers, current clamps, line meters — in the areas, processes or machines that carry real weight. You don’t need to cover the entire plant: the rule of thumb is to start with the <strong>significant energy uses</strong> — the three to six points that account for the bulk of consumption or of uncertainty.</p>
<p>The technology has matured and become cheaper: <strong>IIoT</strong> (Industrial Internet of Things) devices that speak the usual plant protocols—<strong>Modbus, BACnet, M-Bus, even over Wi-Fi and/or LoRaWAN radio</strong> where cabling is expensive—with panel-by-panel installation that rarely requires a shutdown. For an industrial SME, basic metering by line or process has gone from being an engineering project to a job of a few days.</p>
<p>The savings ranges documented by the industry when moving from a main meter to process-level metering run from <strong>20% to 30%</strong> of consumption in facilities with no prior monitoring — not because measuring saves anything in itself, but because of what shows up when you look: idle consumption, equipment running outside operating hours, performance drift, compressed-air leaks, forgotten setpoints.</p>
<h2>Where to start: the five points that almost always pay for the installation</h2>
<ol>
<li><strong>Compressed air</strong> — the king of leaks and idle consumption; almost always the first finding.</li>
<li><strong>Industrial refrigeration and HVAC</strong> — big consumers running on schedules that nobody reviews.</li>
<li><strong>The line or process with the greatest weight in production</strong> — the basis for the cost per unit produced that we’ll look at in the second instalment.</li>
<li><strong>Duplicated processes</strong> — two furnaces, two lines, two cold rooms: metering both turns comparison into a method.</li>
<li><strong>The main feeder of each building or area</strong> — so the total always adds up and any gaps come to light.</li>
</ol>
<p>With those points metered, every new reading is cross-referenced with the main meter’s load profile and the market price — and that’s where the second instalment of this series begins: <strong>what each process really costs</strong>, which we publish on Wednesday.</p>
<h2>The PowerCloud view</h2>
<p>Submetering without a platform is just a collection of little screens on electrical panels. PowerCloud integrates the secondary measurements — via standard plant protocols — alongside the main meter’s load profile and the quarter-hourly price in your contract, and turns them into what actually gets used: comparisons between processes, alerts for consumption that breaks its usual pattern, detection of phantom loads during shutdowns, and the documented measurement boundary that any submission — CAEs, ISO 50001, grants — will sooner or later require. Metering by machine is half the job; having someone look at the data every day is the other half.</p>
<hr />
<p><strong>Does your plant have a single meter for everything?</strong> It’s the most common starting point. We’ll help you design a minimum submetering map — which three to six points to meter first, with what equipment and what return to expect — using your actual main-meter load profile as the basis.</p>
<p>La entrada <a rel="nofollow" href="https://www.powercloud.es/en/industrial-submetering-energy-monitoring-machine-process/">Industrial submetering: the meter tells you how much your plant consumes — machine-level metering tells you who</a> se publicó primero en <a rel="nofollow" href="https://www.powercloud.es/en">Powercloud | Energy monitoring and management</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Goodbye to ‘hourly’ prices: the electricity market now runs in quarter-hours (15 min)</title>
		<link>https://www.powercloud.es/en/electricity-market-15-minute-prices/</link>
		
		<dc:creator><![CDATA[Eduardo Manzanos]]></dc:creator>
		<pubDate>Tue, 25 Nov 2025 15:34:30 +0000</pubDate>
				<category><![CDATA[Electricity Markets]]></category>
		<category><![CDATA[Electricity Tariffs]]></category>
		<category><![CDATA[Energy Costs]]></category>
		<category><![CDATA[Energy Regulation]]></category>
		<guid isPermaLink="false">https://www.powercloud.es/?p=7361</guid>

					<description><![CDATA[<p>From 1 October 2025, the electricity market moves from hourly prices to prices every 15 minutes (96 a day). We explain why this is happening and what opportunities it opens up for businesses and industry.</p>
<p>La entrada <a rel="nofollow" href="https://www.powercloud.es/en/electricity-market-15-minute-prices/">Goodbye to ‘hourly’ prices: the electricity market now runs in quarter-hours (15 min)</a> se publicó primero en <a rel="nofollow" href="https://www.powercloud.es/en">Powercloud | Energy monitoring and management</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p>If you follow the electricity price (or suffer from it <img src="https://s.w.org/images/core/emoji/14.0.0/72x72/1f605.png" alt="😅" class="wp-smiley" style="height: 1em; max-height: 1em;" />), this matters to you:&nbsp;<strong>from 1 October 2025, the day-ahead electricity market in Europe —and therefore in Spain— moves from working by the hour to working in 15-minute intervals</strong>. In other words,&nbsp;<strong>96 prices a day</strong>&nbsp;instead of 24.&nbsp;&nbsp;</p>



<p>It may look like a ‘technical’ change, but it actually marks a turning point in understanding (and optimising) energy in businesses, industry and self-consumption.</p>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<h2 class="wp-block-heading"><strong>What exactly has changed?</strong></h2>



<p>Until now, the wholesale market (the ‘pool’) cleared one price for each hour of the day. Since the change:</p>



<ul>
<li>Each hour is divided into 4 slots:&nbsp;<strong>00:00–00:15, 00:15–00:30, 00:30–00:45, 00:45–01:00</strong>, etc.</li>



<li>So we move to&nbsp;<strong>96 price periods</strong>&nbsp;a day.</li>



<li>OMIE (the Iberian electricity market operator) already reflects this with periods such as&nbsp;<strong>H1Q1</strong>&nbsp;(first quarter of the first hour), etc.&nbsp;&nbsp;</li>
</ul>



<p>And note the date: the ‘historic’ market clearing for the switch took place on&nbsp;<strong>30 September 2025</strong>, already producing the&nbsp;<strong>96 prices</strong>&nbsp;for energy delivered on&nbsp;<strong>1 October</strong>.&nbsp;&nbsp;</p>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<h2 class="wp-block-heading"><strong>Why is this change happening? (the underlying reason)</strong></h2>



<p>The short answer:&nbsp;<strong>because the electricity system no longer behaves ‘by the hour’</strong>.</p>



<p>With renewables (solar and wind) carrying ever more weight, generation can vary considerably within a single hour. With prices every 15 minutes:</p>



<ol start="1">
<li><strong>The price better reflects what it costs to produce electricity at each moment</strong>, matching supply and demand more precisely.&nbsp;&nbsp;</li>



<li><strong>Europe harmonises the electricity market</strong>&nbsp;through the EU single day-ahead coupling (SDAC), so that all countries ‘play’ with the same time unit.&nbsp;&nbsp;</li>



<li>It is in step with the system’s shift towards finer balancing processes: Spain has also been adapting its&nbsp;<strong>imbalance settlement to 15 minutes</strong>, which is key for a more renewable and variable system.&nbsp;&nbsp;</li>
</ol>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<h2 class="wp-block-heading"><strong>Who does it affect?</strong></h2>



<p>It depends on your type of contract and how your consumption is metered:</p>



<ul>
<li><strong>Companies on a pool-indexed tariff</strong>: the ‘reference’ price becomes more granular (and therefore more opportunities to optimise appear… along with more intra-hour variability).</li>



<li><strong>Industry and consumers with a detailed load profile</strong>: this change has much more impact, because the real cost can differ within the same hour.</li>



<li><strong>Households</strong>: in practice, the immediate impact may be limited for many domestic users, depending on how the measure is applied and the effective granularity of meter reading/billing.&nbsp;&nbsp;</li>
</ul>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<h2 class="wp-block-heading"><strong>What opportunities does it open up for a business?</strong></h2>



<p>This is where it gets interesting. With prices every 15 minutes, saving is no longer about ‘changing the hour’ but about ‘moving specific processes’:</p>



<ul>
<li><strong>Shift flexible loads</strong>&nbsp;(HVAC, pumping, charging, staged furnaces, compressors, etc.) to cheaper quarter-hours.</li>



<li><strong>Detect micro-peaks</strong>: sometimes the expensive peak no longer lasts 1 hour… it lasts 15 minutes (and can be avoided).</li>



<li><strong>Optimise self-consumption and batteries</strong>: with finer time detail, you can better fine-tune when to use the grid, when to draw on the battery and when to charge it.</li>



<li><strong>Better analysis of €/unit produced</strong>&nbsp;(€/tonne, €/part, €/batch): if your production and energy data have fine resolution, the KPI improves enormously.</li>
</ul>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<h2 class="wp-block-heading"><strong>How does Powercloud approach it?</strong></h2>



<p>At Powercloud, this change translates into something very concrete:&nbsp;<strong>more precision to turn energy into euros, and euros into decisions</strong>.</p>



<p>Some practical ideas (very ‘shop-floor’):</p>



<ul>
<li>Energy cost&nbsp;<strong>per quarter-hour</strong>&nbsp;by line/process/site.</li>



<li>Alerts if your consumption falls right in the most expensive quarter-hours of the day.</li>



<li>Weekly comparisons: ‘my 10 most expensive quarter-hours’ vs ‘my 10 cheapest quarter-hours’.</li>



<li>Business KPIs (€/t, €/unit) with better traceability.</li>
</ul>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<h2 class="wp-block-heading"><strong>Wrapping up</strong></h2>



<p>The quarter-hourly market is not a passing fad: it is the natural consequence of a more dynamic, more renewable and more European electricity system. And for businesses, it is a clear opportunity:&nbsp;<strong>if you can measure, you can understand; if you can understand, you can optimise</strong>.</p>



<p>If you like, in a future post we can bring this down to earth with&nbsp;<strong>a real example</strong>&nbsp;(e.g. a plant with compressors + self-consumption) and show which decisions emerge when you go from 24 to 96 prices a day.</p>
<p>La entrada <a rel="nofollow" href="https://www.powercloud.es/en/electricity-market-15-minute-prices/">Goodbye to ‘hourly’ prices: the electricity market now runs in quarter-hours (15 min)</a> se publicó primero en <a rel="nofollow" href="https://www.powercloud.es/en">Powercloud | Energy monitoring and management</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Energy management system vs Excel</title>
		<link>https://www.powercloud.es/en/energy-management-system-vs-excel/</link>
		
		<dc:creator><![CDATA[Eduardo Manzanos]]></dc:creator>
		<pubDate>Sat, 09 Dec 2023 10:43:27 +0000</pubDate>
				<category><![CDATA[Energy Management]]></category>
		<category><![CDATA[ISO 50001]]></category>
		<category><![CDATA[SaaS Platforms]]></category>
		<category><![CDATA[excel]]></category>
		<guid isPermaLink="false">https://www.powercloud.es/?p=6772</guid>

					<description><![CDATA[<p>How much time and how many errors can a company save by moving its energy tracking from Excel to an energy management system? The exact figures depend on each organisation...</p>
<p>La entrada <a rel="nofollow" href="https://www.powercloud.es/en/energy-management-system-vs-excel/">Energy management system vs Excel</a> se publicó primero en <a rel="nofollow" href="https://www.powercloud.es/en">Powercloud | Energy monitoring and management</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p>How much time and how many errors can a company save by moving its energy tracking from Excel to an energy management system? The exact figures depend on each organisation and on the system chosen, but the typical benefits fall into four areas:</p>



<ol>
<li><strong>More efficient data handling</strong>: an automated energy management system greatly reduces the time spent collecting and analysing data. In Excel, data is entered and manipulated by hand; automation can cut that effort by 50% to 70% or more, depending on the complexity and volume of the data.</li>



<li><strong>Fewer errors</strong>: manual data entry and analysis in spreadsheets are prone to human error. By automating data collection and processing, an energy management system can reduce errors by between 30% and 60%, depending on how effective the system is and how accurate the previous manual methods were.</li>



<li><strong>Faster analysis and reporting</strong>: energy management systems usually include advanced analysis and reporting tools, which can cut the time spent on these tasks by 40% to 60% compared with Excel.</li>



<li><strong>Real-time monitoring and alerts</strong>: monitoring consumption in real time and receiving automatic alerts about anomalies or excess consumption has no real equivalent in Excel, and is one of the biggest steps forward in energy management.</li>
</ol>



<p>Want to see what this would mean for your organisation? <a href="https://www.powercloud.es/en/contact/">Get in touch</a> and we will show you Powercloud working with your own data.</p>

<p>La entrada <a rel="nofollow" href="https://www.powercloud.es/en/energy-management-system-vs-excel/">Energy management system vs Excel</a> se publicó primero en <a rel="nofollow" href="https://www.powercloud.es/en">Powercloud | Energy monitoring and management</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>